Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

INSPECTION    
        
AMBIENT AIR TEMPERATURE SENSOR CHECK

CAUTION:  The ambient air temperature sensor should be checked without removing it. If the sensor is removed, it is no longer serviceable.    

Measure the resistance between the sensor terminals under at least two temperatures. The resistance values should meet the values shown.    

NOTE:  The temperature should be within the shown range.