Eclipse V6-3.8L (6G75) (2006)
the front and rear sides of the seatback about eight times each to remove the friction.
3. To execute accuracy check and calibration, operate scan tool MB991958 as follows.
1. Select "Interactive Diagnosis".
2. Select "Special Function".
3. Select "Seat Weight Sensor Accuracy Check".
4. For accuracy check 30 kg (66 pounds), slide the seat to the front end, and put a 30 kg (66 pounds) weight on the center of the seat cushion.
Then, carry out the friction removal in step (2) and press the OK button to execute accuracy check.
NOTE: If there is not a 30 kg (66 pounds) weight, load a square object of 30 to 40 kg (66 to 88 pounds). At this time, operate the arrow
button of the weight input part on MUT-III to input the loaded weight value.