Eclipse V6-3.8L (6G75) (2006)
7. Unload the weight, check the seat installation condition and carry out the friction removal in step (2) again, and press the OK button. When the
execution dialog is displayed, press the OK button again to execute the calibration.
8. The calibration has been completed when the screen as shown in the illustration is displayed. Press the OK button to return to the screen of
step (4), and carry out the same procedure.
9. When the screen for the accuracy check of 0 kg (0 pound) is displayed, unload the weight and slide the seat to the rear end. Then, carry out the
friction removal in step (2) and press the OK button to execute the accuracy check.