mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 2012 > < Symptom Related Diagnostic Procedures|Page 2010
Page 1
background image

Idle Air Control Motor: Oscilloscope Patterns and Waveforms

STEPPER MOTOR MEASUREMENT METHOD 

1. Disconnect the stepper motor connector, and connect the special tool (test harness:  MD998463) in between.

2. Connect the analyzer special patterns pickup to the stepper motor-side connector terminal 1 (red clip on the special tool), terminal 3 (blue clip),

terminal 4 (black clip) and terminal 6 (yellow clip) respectively.

ALTERNATE METHOD (TEST HARNESS NOT AVAILABLE) 

1. Connect the analyzer special patterns pickup to ECM terminal 4, connection terminal 5, connection terminal 17, and connection terminal 18

respectively.

STANDARD WAVE PATTERN OBSERVATION CONDITIONS 

STANDARD WAVE PATTERN 

WAVE PATTERN OBSERVATION POINTS  

Check that the standard wave pattern appears when the stepper motor is operating.
Point A:  Presence or absence of induced voltage from the motor turning.
Point B:  Height of coil reverse voltage