Eclipse GS L4-2350cc 2.4L SOHC MFI (2002)
Shift Interlock: Component Tests and General Diagnostics
SHIFT LOCK MECHANISM CHECK
1. Carry out the following inspections.
2. When the operations are defective, adjust the shift lock cable as follows:
1. Remove the floor console.
2. Shift selector lever to "P" position.
3. Loosen the locking nut of shift lock cable.
4. Tighten the locking nut so that the end of the shift lock cable comes above the red marking of the lock cam.
5. Install the floor console.
3. After adjusting, check the operation once more. If the operation is still incorrect, replace the shift lock cable.