8. Set the lever for the inside/outside air changeover on the heater control assembly to the air-recirculation position.
9. Set the inside/outside air changeover damper lever of the blower unit to air-recirculation position (with the inside/outside air changeover damper

lever touched to the stopper of the blower case) and install the cable to the lever pin.

10. Push the outer cable in the direction of the arrow so that there is no looseness and then secure it with the clip.

INSPECTION

-

Check each knob and lever for proper operation and possible damage.

-

Check the connection between the lever and cable.

-

Check that the cable sides properly.

-

Check the illumination light for a possible broken filament.

BLOWER SWITCH CONTINUITY CHECK 