Eclipse Spyder GT V6-3.0L SOHC (2002)
STEP 9. Check the wiring harness between combination meter connector C-42 and ETACS-ECU connector C-118.
Q: Is the wiring harness between combination meter connector C-42 and ETACS-ECU connector C-118 in good condition?
YES: No action to be taken.
NO: Repair the wiring harness. Check that the high-beam indicator light illuminates normally.
Inspection Procedure J-9
Headlight, Tail Light: Headlight Automatic Shutdown Function does not Work Normally.
NOTE: This troubleshooting requires use of scan tool MB991502 and SWS monitor kit MB991862. For details of how to use the SWS monitor, refer
to "How to use SWS monitor."
Headlight Automatic Shut-down Function
CIRCUIT OPERATION
The ETACS-ECU operates the headlight automatic shutdown function according to the following signals:
-
Ignition switch (IG1): OFF
-
Driver's door switch: ON
-
Tail light switch: ON
-
Headlight switch: ON
The ETACS-ECU operates the headlight automatic shutdown function under the following conditions:
-
Ignition key: Other than "ON" position