STEP 6. Check the wiring harness between key reminder switch connector C-88 and ETACS-ECU connector C-117.
Q: Is the wiring harness between key reminder switch connector C-88 and ETACS-ECU connector C-117 in good condition?
YES: Replace the ETACS-ECU. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal from the key
reminder switch should be normal.
NO: Repair the wiring harness. If the functions, which are described in "CIRCUIT OPERATION", work normally, the input signal from the key
reminder switch should be normal.
Inspection Procedure P-2
The ETACS-ECU does not Receive Any Signal from the Hazard Warning Light Switch.
Hazard Warning Switch Input Circuit
Connectors
CIRCUIT OPERATION
The ETACS-ECU operates the following functions or systems according to signal from the hazard warning light switch:
-
Hazard warning light
-
Keyless entry system (registering the encrypted code)
TECHNICAL DESCRIPTION (COMMENT)