mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations
Page 1
background image

Refrigerant Temperature Sensor: Technical Service Bulletins
A/C - Refrigerant Temperature Switch Manual Correction

NO.: TSB-93-55-006
DATE: December, 1993
MODEL: 1994 Galant

SUBJECT:

REFRIGERANT TEMPERATURE SWITCH -
SERVICE MANUAL REVISION

[TSB Revision: TSB-93-55-006]

PURPOSE

This bulletin corrects the A/C refrigerant temperature switch symbol and operation conditions shown in the 1994 Galant Service Manual. The illustration
in the service manual shows the switch as a resistive load device and (more importantly) reverses the temperature operation conditions.

Please make the indicated service manual revision, and as reference to this TSB, please write this TSB number in the TSB revision box on the affected
service manual page.

CORRECTED INFORMATION

The A/C refrigerant temperature switch specifications:

OFF-ON : 90~C (194~ F) 
ON-OFF : 145~C (293~F)

SERVICE MANUAL REVISION

1994 Galant, Volume 2, page 115.

Cross out the switch information and write in "REFER TO TSB-93-55-006 FOR CORRECTED ILLUSTRATION" as shown.

Restraint Systems > < Refrigerant Pressure Sensor / Switch, HVAC|Locations