Galant L4-2.0L SOHC (1989)
Harness Inspection
Component Inspection
Ignition Coil
(1) Measurement of the primary coil resistance. Measure the resistance of the positive (+) terminal and negative (-) terminal of the ignition coil.
Standard value: 0.72-0.88 k/Ohms
(2) Measurement of the secondary coil resistance. Measure the resistance of the positive (+) terminal and the high-voltage terminal.
Standard value: 10.89-13.31 k/Ohms
Ignition Power Transistor