Galant L4-2.0L SOHC (1989)
REVISIONS
1.
The voltage required to operate the transistor switching circuit inside the power transistor is very low. The 15 volts specified in the Service Manual
is incorrect, all that is necessary is a 1.5 volt dry cell battery as shown in the illustrations. Please make the changes shown below.
2.
The first test procedure is reading continuity through the power transistor, and polarity of the test meter could affect results. Please change the
polarity as shown below.
3.
The second test procedure needs to have battery polarity reversed so that it will match the accompanying text in the Service Manual. Please make
the changes as shown below.