mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

3. SES/MIL Lamp Does Not Illuminate With Ignition Switch on|Page 3249 > < 3. SES/MIL Lamp Does Not Illuminate With Ignition Switch on
Page 2
background image

CONNECTORS

DIAGNOSIS 
Required Special Tool:
MB991502: Scan Tool (MUT-II)

CAUTION:  To prevent damage to the scan tool, turn the ignition switch "OFF" before connecting or disconnecting the scan tool.

STEP 1.

Using scan tool MB991502, check data list item 16: Power Supply Voltage.
-

Voltage should be approximately 12 volts (battery positive voltage).
If within specifications, go to Step 2.
If not within specifications, refer to INSPECTION PROCEDURE 29 - Power Supply and Ignition Switch - IG System.

STEP 2.

Check the circuit at the PCM connector C-39.
1. Disconnect connector C-39 and measure at the harness side.
2. Turn the ignition switch "ON."
3. Using a jumper wire, ground terminal 22 to the ground.

-

The service engine soon/malfunction indicator lamp should illuminate.

4. Turn the ignition switch "OFF."

If the lamp does not illuminate, go to Step 3. If the lamp illuminate, go to Step 6.

3. SES/MIL Lamp Does Not Illuminate With Ignition Switch on|Page 3249 > < 3. SES/MIL Lamp Does Not Illuminate With Ignition Switch on