mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3052 > < Initial Inspection and Diagnostic Overview|Page 3050
Page 65
background image

<When using a voltmeter>

1. Use special tool MB991529 to connect a voltmeter between ground terminal 4 or 5 and ETACS-ECU terminal 9 of the data link connector.
2. Check that the voltmeter indicator deflects once when the input signal enters.

If a defect appears, check the input signal circuit from the windshield intermittent wiper interval adjusting knob. Refer to Inspection Procedure
N-16.
If no detect appears, replace the front-ECU or ETACS-ECU. The windshield intermittent wiper interval should be changed.

Inspection Procedure F-5

Windshield Washer Motor Driver Circuit

Initial Inspection and Diagnostic Overview|Page 3052 > < Initial Inspection and Diagnostic Overview|Page 3050