Galant VR4 AWD L4-1997cc 2.0L DOHC Turbo (1992)
Harness Inspection
Ignition Coil
(1) Measurement of the primary coil resistance.
(2) Measure the resistance between connector terminals 3 and 2 (the coils at the No.1 and No.4 cylinder sides) of the ignition coil, and between
terminals 3 and 1 (the coils at the No. 2 and No.3 cylinder sides).
Standard value: 0.77-0.95 Ohms
(3) Measurement of secondary coil resistance.
(4) Measure the resistance between the high-Voltage terminals for the No. 1 and No.4 cylinders, and between the high-Voltage terminals for the No.2
and No.3 cylinders.
Standard value: 10.3-13.9 K Ohms
Caution:Be sure, when measuring the resistance of the secondary coil, to disconnect the connector of the ignition coil.
Ignition Power Transistor
Note: An analog type circuit tester should be used
No. 1-No. 4 coil side