mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Non Trouble Code Components|Page 1116 > < Non Trouble Code Components|Page 1114
Page 1
background image

Ignition Switch: Testing and Inspection
Ignition Switch-ST and Park/Neutral (Inhibitor) Switch (A/T)

Inhibitor Switch Circuit

To test the inhibitor switch, proceed as follows.

COMPONENT TEST

1. Disconnect the inhibitor switch connector.
2. Using an ohm meter, check for continuity between inhibitor switch terminals 8 and 9.

Continuity

Exists W/transmission in park.

Continuity

Exists W/transmission in neutral.

Continuity

Does not exist W/transmission in any other position.

HARNESS TEST:
1. With the transmission shift indicator in park or neutral, disconnect the ECU connector and the inhibitor switch connector.
2. Turn the key to the START position.
3. Using a voltmeter, check the voltage between inhibitor switch harness terminal 8 and ground.

Voltage:

System Voltage.

4. Reconnect the ECU harness connector and turn the key to the ON position
5. Using a voltmeter, check the voltage between the inhibitor harness connector terminal 8 and ground

Voltage:

No Voltage.

Non Trouble Code Components|Page 1116 > < Non Trouble Code Components|Page 1114