mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Air Cleaner Housing > < Idle Speed|Specifications|Page 891
Page 2
background image

Standard value: Approximately 10° BTDC

7. Check the idle speed. Select item number 2 and take a reading of the idle speed.

Curb idle speed: 700 ± 100 r/min

NOTE:The idle speed is controlled automatically by the idle air control system.

8. If the idle speed is outside the standard value, refer to Multiport Fuel Injection (MFI) - Multiport Fuel Injection (MFI) Diagnosis - Symptom

Chart.

NOTE: Ignition timing fluctuates about ± 7° Before Top Dead Center, even under normal operating condition.

NOTE: It is automatically further advanced by about 5° to 10° Before Top Dead Center at higher altitudes.

9. Remove the timing light.

CAUTION
To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting
scan tool MB991958.
 

10. Disconnect scan tool MB991958 from the data link connector.

Air Cleaner Housing > < Idle Speed|Specifications|Page 891