Lancer L4-2.4L SOHC (2005)
-
MB991813: SWS Monitor Kit
-
MB991806: SWS Monitor Cartridge
-
MB991812: SWS Monitor Harness (For Column-ECU)
-
MB991822: Probe Harness
CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958.
1. Ensure that the ignition switch is at the "LOCK" (OFF) position.
2. Start up the personal computer.
3. Connect special tool MB991827 to special tool MB991824 and the personal computer.
4. Connect special tool MB991911 to special tool MB991824.
5. Connect special tool MB991911 to the data link connector.
6. Connect special tool MB991812 to special tool MB991806.
7. Connect special tool MB991806 to special tool MB991824.
8. Turn the power switch of special tool MB991824 to the "ON" position.
NOTE: When special tool MB991824 is energized, special tool MB991824 indicator light will be illuminated in a green color.
9. Start the MUT-III system on the personal computer.
10
Connect the SWS monitor to the vehicle.