mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2072 > < Initial Inspection and Diagnostic Overview|Page 2070
Page 398
background image

1. Disconnect backup light switch connector B-111 and measure the voltage available at the wiring harness side of the connector.
2. Turn the ignition switch to the "ON" position.

3. Measure the voltage between terminal 1 and ground.

-

The voltage should equal approximately 12 volts (battery positive voltage).

Q: Is the measured voltage approximately 12 volts (battery positive voltage)?

YES: Go to Step 5.

NO: Go to Step 4.