mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2143 > < Initial Inspection and Diagnostic Overview|Page 2141
Page 19
background image

Check the following ECUs:

-

ETACS-ECU

-

Column-ECU

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958. Connect the DLC harness before connecting the column-ECU harness. Be sure to connect SWS monitor kit
MB991813 after turning on scan tool MB991958.

1. Connect scan tool MB991958 to the data link connector.
2. Connect SWS monitor kit MB991813 to the column switch connector.
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate scan tool MB991958 according to the procedure below to display "ECU COMM CHK."

a. Select "SYSTEM SELECT.
b. Select "SWS.
c. Select "SWS MONITOR.
d. Select "ECU COMM CHK.

5. Scan tool MB991958 should show "OK" on the "ECU COMM CHK" menus for both the "ETACS ECU" and the "COLUMN ECU" menus.

Q: Are "OK" displayed on both the "ETACS ECU" and "COLUMN ECU" menus?

"OK" are displayed for all the items: . Go to Step 2.

"NG" is displayed on the "COLUMN ECU" menu: . Go to Step 6.

"NG" is displayed on the "ETACS ECU" menu: . Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is not possible."

"NG" are displayed for all the items: . Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is not possible."

Initial Inspection and Diagnostic Overview|Page 2143 > < Initial Inspection and Diagnostic Overview|Page 2141