2. Measure the resistance value between terminal 4 and ground.

-

The resistance should equal 2 ohms or less.

Q: Is the measured resistance 2 ohms or less?

YES: Go to Step 7.

NO: Go to Step 6.

STEP 6. Check the wiring harness between column switch connector C-206 (terminal 4) and the ground.

NOTE:  Also check joint connector C-06 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If joint connector C-06
is damaged, repair or replace the damaged component(s) as described in Harness Connector Inspection.

Q: Is the wiring harness between column switch connector C-206 (terminal 4) and the ground in good condition?

YES: No action is necessary and testing is complete.

NO: The wiring harness may be damaged or the connector(s) may have loose, corroded or damaged terminals, or terminals pushed back in the
connector. Repair the wiring harness as necessary. The system should communicate with the column switch (column-ECU) normally.