mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2468 > < Initial Inspection and Diagnostic Overview|Page 2466
Page 344
background image

2. Connect SWS monitor kit MB991813 to the column switch connector.
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate scan tool MB991958 according to the procedure below to display "ECU COMM CHK."

a. Select "SYSTEM SELECT."
b. Select "SWS."
c. Select "SWS MONITOR."
d. Select "ECU COMM CHK."

5. Scan tool MB991958 should show "OK" on the "ECU COMM CHK" menu for the "ETACS ECU" menu.

Q: Is "OK" displayed on the "ETACS ECU" menu?

YES: Go to Step 3.

NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is not possible."

STEP 3. Check the input signal by using "DATA LIST" menu of the SWS monitor.
Check the input signals from the following switches:

-

Ignition switch: OFF

-

Driver's and front passenger's door: open

1. Operate scan tool MB991958 according to the procedure below to display "ETACS ECU."

a. Select "SYSTEM SELECT."
b. Select "SWS."
c. Select "SWS MONITOR."
d. Select "DATA LIST."
e. Select "ETACS ECU."

Initial Inspection and Diagnostic Overview|Page 2468 > < Initial Inspection and Diagnostic Overview|Page 2466