Intake Air Temperature Sensor: Testing and Inspection
Intake Air Temperature Sensor

INTAKE AIR TEMPERATURE SENSOR CHECK 

1. Disconnect the mass airflow sensor connectors.
2. Measure resistance between terminal No.1 and No.4.

Standard value:
13 - 17 kOhms [at -20°C (-4°F)] 
5.3 - 6.7 kOhms [at 0°C (32°F)] 
2.3 - 3.0 kOhms [at 20°C (68°F)] 
1.0 - 1.5 kOhms [at 40°C (104°F)] 
0.56 - 0.76 kOhms [at 60°C (140°F)] 
0.30 - 0.45 kOhms [at 80°C (176°F)] 

3. If not within specifications, replace the mass airflow sensor.
4. Measure resistance while heating the sensor using a hair dryer.

5. If resistance does not decrease as heat increases, replace the mass airflow sensor.