Refrigerant Pressure Sensor / Switch: Specifications

GENERAL SPECIFICATIONS

ITEM..............................................................................................................................................................................MANUAL AIR CONDITIONING

Dual pressure switch kPa (psi)

High-pressure switch
ON to OFF...........................................................................................................................................................................................................2,942 (426.7)
OFF to ON...........................................................................................................................................................................................................2,354 (341.4)

Low-pressure switch
ON to OFF................................................................................................................................................................................................................196 (28.4)
OFF to ON................................................................................................................................................................................................................221 (32.1)