mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Reserve Tank Fluid (For Active Center Differential and Active Yaw Control System) (Check Fluid Level)|Page 1031 > < Fluid - Transfer Case|Capacity Specifications|Page 1028
Page 1
background image

Fluid - Transfer Case: Service and Repair
Reserve Tank Fluid (For Active Center Differential and Active Yaw Control System) (Check Fluid
Level)

RESERVE TANK FLUID (FOR ACTIVE CENTER DIFFERENTIAL AND ACTIVE YAW CONTROL SYSTEM) (CHECK FLUID LEVEL)

FLUID LEVEL CHECK

[WHEN THE SCAN TOOL IS NOT USED]

1. Remove the trunk room side trim lid on the right of the trunk room.
2. If the vehicle has been run, leave it for 90 min. or more in an ordinary temperature {10 -30 degrees C (50 -86 degrees F)} to allow the accumulator

internal pressure to drop.

NOTE: If the ambient temperature is 10 degrees C (50 degrees F) or less, allow more time to leave the vehicle to stand idle.

3. Check that the oil reservoir fluid level is in between MAX and MIN.
4. If the fluid level is not in between MAX and MIN, fill the specified fluid.

Specified fluid: DIAMOND ATF-SP III

5. Install the trunk room side trim lid.

[WHEN THE SCAN TOOL IS USED]

1. Remove the trunk room side trim lid on the right of the trunk room.

CAUTION:
Turn the ignition switch to the "LOCK (OFF)" position before connecting or disconnecting the scan tool.

2. Set the scan tool to the 16-pin data link connector. (Refer to See: Powertrain Management/Computers and Control Systems/Testing and

Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting.)

3. Turn the ignition switch to the ON position.
4. Using the scan tool, forcibly activate the hydraulic unit (item No. 03) to reduce the pressure inside the accumulator. (Refer to Actuator Test Table 

See: Brakes and Traction Control/Antilock Brakes / Traction Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Actuator
Test Reference Table.)

NOTE:
^

With the forced activation (oil level check mode), the hydraulic unit direction valve is operated 20 times to right and left, and then the
operation is canceled automatically. Also, using the clear key on the scan tool, the activation can be forcibly canceled.

^

When the functions are suspended by the fail-safe function, the hydraulic unit cannot be forcibly activated.

5. Check that the oil reservoir fluid level is in between MAX and MIN.
6. If the fluid level is not in between MAX and MIN, fill the specified fluid.

Specified fluid: DIAMOND ATF-SP III

Reserve Tank Fluid (For Active Center Differential and Active Yaw Control System) (Check Fluid Level)|Page 1031 > < Fluid - Transfer Case|Capacity Specifications|Page 1028