mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2577 > < Initial Inspection and Diagnostic Overview|Page 2575
Page 224
background image

1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.

3. Select "TURN SIGNAL - TURN-SIG RH" (FUNCTION DIAG), and check that normal conditions are displayed on the items described in the

table.

Q: Are normal conditions displayed on the "T/S RH SW" and "IG SW(IG1)"?

YES: Replace the ETACS-ECU. Check that the turn-signal lights illuminate normally.

NO: 
-

Normal condition is not displayed on the "T/S RH SW": Refer to Inspection Procedure L-5 "ETACS- ECU does not receive a signal from
the turn-signal RH switch."

-

Normal condition is not displayed on the "IG SW (IG1)":  Refer to Inspection Procedure L-2 "ETACS-ECU does not receive a signal from
the ignition switch (IG1)."

Inspection Procedure J-2

Flasher Timer: Hazard Warning Lights do not Illuminate

Initial Inspection and Diagnostic Overview|Page 2577 > < Initial Inspection and Diagnostic Overview|Page 2575