2. Apply a coating of the specified fluid to the outside of the ball bearing. Using the special tools, press the ball bearing into the valve housing.

Specified fluid:  Automatic transmission fluid "DEXRON II"

>G<Seal Ring Installation

1. Kneed the seal ring to soften it.
2. Apply the specified fluid to the seal ring, and install to the rack groove.

Specified fluid:  Automatic transmission fluid "DEXRON II"

3. Insert the tapered side of the special tool from the pinion gear side, and compress the seal ring.

>H<Oil Seal Installation

Use the special tool to press the oil seal into the valve housing. The upper surface of the oil seal should project outward approximately 1 mm (0.04
inch) from the housing edge surface.

CAUTION:  If the oil seal is flush with or lower than the housing edge, it will cause oil leaks and require reassembly.

>I<End Plug Installation

1. Apply the specified sealant to the threaded part of the end plug.

Specified sealant: 3M ATD Part No.8661 or equivalent

2. Secure the threaded portion of the end plug at two places by using a punch.