Montero V6-3.8L SOHC (2005)
Diagnosis Table
8. After inspection, disconnect the scan tool immediately after turning the ignition switch to the "LOCK" (OFF) position.
How to Read Data List
HOW TO READ DATA LIST
Required Special Tools:
^
MB991958: Scan Tool (MUT-III Sub Assembly)
^
MB991824: Vehicle Communication Interface (V.C.I.)
^
MB991827: MUT-III USB Cable
^
MB991911: MUT-III Main Harness B
CAUTION: To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958.
1. Connect scan tool MB991958 to the data link connector.
2. Turn the ignition switch to the "ON" position.
3. Select "Interactive Diagnosis" from the start-up screen.
4. Select "System select."
5. Choose "HBB" from the "CHASSIS" tab.
6. Select "MITSUBISHI."
7. Select"Data List."
8. Choose an appropriate item and select the "OK" button.
How to Perform Actuator Test
HOW TO PERFORM ACTUATOR TEST
Required Special Tools: