mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Reading and Clearing Diagnostic Trouble Codes|Page 6068 > < Reading and Clearing Diagnostic Trouble Codes|Page 6066
Page 22
background image

STEP 8. Check the harness wires between RV meter connector D-07 (terminal 23 and 31) and ambient air temperature sensor connector A-29
(terminal 1 and 2).

NOTE:  After inspecting intermediate connector D-28 inspect the wires. If intermediate connector D-28 is damaged, repair or replace it. Refer to
Harness Connector Inspection.

Q: Are harness wires between RV meter connector D-07 (terminal 23 and 31) and ambient air temperature sensor connector A-29 (terminal 1 and 2) in
good condition?

YES: Go to Step 9.

NO: Repair or replace them. Refer to Harness Connector Inspection.

STEP 9. Recheck for malfunction.

Q: Is a malfunction eliminated?

YES: If no malfunctions are found in all steps, an intermittent malfunction is suspected. Refer to How to Use Troubleshooting/Inspection Service
Points - How to Cope with Intermittent Malfunction.

NO: Replace the RV meter.

Inspection Procedure 5

The Compass does not Indicate Normally.

TECHNICAL DESCRIPTION (COMMENT)

The geomagnetism sensor integrated in the RV meter is abnormal, or it is seemed that the indication is affected by some nearby magnetized matter. 

TROUBLESHOOTING HINTS

Malfunction of the RV meter

DIAGNOSIS

STEP 1. Check the geomagnetism sensor mode in service mode.

1. When the adjusting switch is continuously pressed for more than five seconds, the reception sound (pip sound) is heard and at the same time the

service function is activated to display the service mode screen.

2. Press the adjusting switch with the ignition switch at the "LOCK" (OFF) position. Then while keeping the switch on the pressed condition, turn the

ignition switch to "ACC" position. 

3. Check the geomagnetism sensor at the geomagnetism sensor mode.

Reading and Clearing Diagnostic Trouble Codes|Page 6068 > < Reading and Clearing Diagnostic Trouble Codes|Page 6066