Montero V6-3.8L SOHC (2005)
3. Install the bulb to the combination meter, and then measure the resistance value between connector D-04 terminal 32 and connector D-03 terminal
62. The measured resistance value should be roughly the same as the value measured in Step (2).
Q: Are these two resistance values extremely different?
YES: Repair or replace the combination meter (printed circuit board). Verify that the seat belt warning light illuminates normally.
NO: (much the same) : Go to Step 9.
STEP 9. Measure at combination meter connector D-03 in order to check the ignition switch (IG1) line of the power supply to the combination
meter.
1. Disconnect combination meter connector D-03, and measure at the wiring harness side.
2. Turn the ignition switch to the "ON" position.
3. Measure the voltage between terminal 62 and ground.
-
The voltage should be approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
YES: Go to Step 11.
NO: Go to Step 10.