Montero V6-3.8L SOHC (2005)
STEP 6. Check combination meter connector D-04 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is combination meter connector D-04 in good condition?
YES: Go to Step 7.
NO: Repair or replace the damaged component(s). Refer to Harness Connector Inspection. Verify that the high-beam indicator light illuminates
normally.
STEP 7. Check the fusible link (2) line of the power supply circuit to the combination meter. Test at combination meter connector D-04.
1. Disconnect combination meter connector D-04 and measure the voltage available at the wiring harness side of the connector.
2. Measure the voltage between terminal 34 and ground.
-
The voltage should equal 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
YES: Go to Step 9.
NO: Go to Step 8.