Montero V6-3.8L SOHC (2005)
disconnecting scan tool MB991958.
1. Connect the special tool. Refer to "How to connect SWS monitor". See: Reading and Clearing Diagnostic Trouble Codes/How to Connect SWS
Monitor
2. Operate scan tool MB991958 according to the procedure below to display "F.FOG LIGHT"
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "FUNCTION DIAG."
5. Select "LIGHTING."
6. Select "F.FOG LIGHT."
3. Check that normal conditions are displayed on the items described in the given table.
Q: Are normal conditions displayed on the "IG SW(IG1)" and "F.FOG LIGHT"?
Normal conditions are displayed for all the items : Go to Step 3.
Normal condition is not displayed on the "IG SW(IG1)" : Refer to Inspection Procedure O-2 "ETACS-ECU does not receive any signal from
the ignition switch (IG1)."
Normal condition is not displayed on the "F.FOG LIGHT" : Refer to Inspection Procedure O-3 "ETACS-ECU does not receive any signal
from the fog light switch5."