mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 3354 > < Diagram Information and Instructions|Page 3351
Page 1
background image

Ignition Coil: Component Tests and General Diagnostics

INSPECTION USING SCAN TOOL

COIL RESISTANCE CHECKS
Primary coil resistance

Measure the resistance at the positive (+) terminal and negative (-) terminal of the ignition coil.

Standard value: 0.72-0.88 Ohms

Secondary coil resistance

Measure the resistance at the positive (+) terminal and the high voltage terminal.

Standard value: 10.3-13.9k Ohms

IGNITION POWER TRANSISTOR
NOTE:
  An analog-type ohmmeter should be used.

1. Connect the negative (-) terminal of a 1.5 V power supply to terminal (2) of the ignition power transistor and then check whether there is

continuity between terminal (3) and terminal (2) when terminal (1) and the positive (+) terminal are connected and disconnected.

NOTE:  Connect the (-) probe of the ohmmeter to terminal (3).

-

With Terminal (1) and (+) terminal connected: Continuity

-

With Terminal (3) and terminal (2) connected: Continuity

Component Tests and General Diagnostics|Page 3354 > < Diagram Information and Instructions|Page 3351