mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 2466 > < Component Tests and General Diagnostics
Page 2
background image

4. Connect the positive (+) terminal of a power supply (approximately 6 V) to the white clip and the green clip.
5. Connect the negative (-) terminal of the power supply to each clip as described in the following steps. Then check whether or not the stepper motor

vibrates slightly as it operates.
(1) Connect the negative (-) terminal of the power supply to the red and black clip.
(2) Connect the negative (-) terminal of the power supply to the blue and black clip.
(3) Connect the negative (-) terminal of the power supply to the blue and yellow clip.
(4) Connect the negative (-) terminal of the power supply to the red and yellow clip.
(5) Connect the negative (-) terminal of the power supply to the red and black clip.
(6) Repeat the tests in sequence from (5) to (1) to test opposite movement of the IAC.

6. If vibration is detected during the test, the stepper motor can be considered to be normal.

Component Tests and General Diagnostics|Page 2466 > < Component Tests and General Diagnostics