mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Oxygen Sensor|Front|Page 2494 > < Oxygen Sensor|Front|Page 2492
Page 3
background image

2. Make sure that there is continuity [7-40 ohm at 20°C (68°F)] between terminal 1 (red clip of special tool) and terminal 3 (blue clip of special tool)

on the heated oxygen sensor connector.

NOTE: If the scan tool does not display the standard value although no abnormality is found by the above mentioned continuity test and harness
check, replace the heated oxygen sensor (rear).

NOTE: For removal and installation of the oxygen sensor refer to Exhaust Pipe and Main Muffler.

3. If there is no continuity, replace the heated oxygen sensor.

<RIGHT BANK HEATED OXYGEN SENSOR (REAR) - CALIFORNIA>   

1. Disconnect the heated oxygen sensor connector and connect special tool, MB991316, to the connector on the heated oxygen sensor side.
2. Make sure that there is continuity [7-40 ohm at 20°C (68°F)] between terminal 1 (red clip of special tool) and terminal 3 (blue clip of special tool)

on the heated oxygen sensor connector.

NOTE: If the scan tool does not display the standard value although no abnormality is found by the above mentioned continuity test and harness
check, replace the heated oxygen sensor (rear).

NOTE: For removal and installation of the oxygen sensor refer to Exhaust Pipe and Main Muffler.

3. If there is no continuity, replace the heated oxygen sensor.

Oxygen Sensor|Front|Page 2494 > < Oxygen Sensor|Front|Page 2492