mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Relays and Modules - Restraint Systems > < Component Tests and General Diagnostics|Page 193
Page 2
background image

Wave Pattern Observation Points 

Point: Condition of wave pattern build-up section and maximum voltage (Refer to abnormal wave pattern examples 1 and 2.

EXAMPLES OF ABNORMAL WAVE PATTERNS 

Example 1 (Wave pattern during engine cranking) 

-

Cause of problem
Open-circuit in ignition primary circuit

-

Wave pattern characteristics
Top-right part of the build-up section cannot be seen and voltage value is approximately 2 volts too low.

Example 2 (Wave pattern during engine cranking) 

-

Cause of problem
Malfunction in ignition power transistor

-

Wave pattern characteristics
Power voltage results when the ignition power transistor is "ON".

Relays and Modules - Restraint Systems > < Component Tests and General Diagnostics|Page 193