mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Housing Assembly HVAC > < A/C - Pulsating/Rattle Noise|Page 5107
Page 2
background image

INSTALLATION SERVICE POINT

>>A<< SUCTION HOSE/RECEIVER ASSEMBLY INSTALLATION

CAUTION:  Seal the hoses completely, otherwise the compressor oil and receiver will absorb water vapor easily, possibly damaging the compressor and
deteriorating performance.

Plug the disconnected hose, pipe, condenser, compressor and heater unit nipple to prevent foreign matter from getting into them.

Compressor oil: SUN PAG56
Quantity: Suction hose: 10 cu.cm (0.3 floz)

Receiver assembly: 10 cu.cm (0.3 floz)

Housing Assembly HVAC > < A/C - Pulsating/Rattle Noise|Page 5107