Intake Air Temperature Sensor: Testing and Inspection

INTAKE AIR TEMPERATURE SENSOR CHECK

1. Disconnect the volume air flow sensor connectors.

2. Measure resistance between terminals 5 and 6.

Standard value: 2.3 - 3.0 ohms at 20°C (68°F)

0.30 - 0.42 ohms at 80°C (176°F) 

-

If not within specifications, replace the volume air flow sensor.

3. Measure resistance while heating the sensor using a hair dryer.

Normal condition

4. If resistance does not decrease as heat increases, replace the volume air flow sensor assembly.