mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Oscilloscope Check|Page 2516 > < Oscilloscope Check
Page 2
background image

Wave Pattern Observation Points

1. Check that the standard wave pattern appears when the idle air control motor is operating.

Point A:

Presence or absence of induced electromotive force from the motor turning. (Refer to abnormal wave pattern.)

Point B:

Height of coil back electromotive force

Examples of Abnormal Wave Patterns

Example 1

-

Cause of problem
Malfunction of motor. (Motor is not operating.)

-

Wave pattern characteristics
Induced electromotive force from the motor turning does not appear.

Example 2

-

Cause of problem
Open circuit in the line between the idle air control motor and the PCM.

-

Wave pattern characteristics
Current is not supplied to the motor coil on the open circuit side. (Voltage does not drop to 0 volt.) Furthermore, the induced electromotive force
wave pattern at the normal side is slightly different from the normal wave pattern.

Oscilloscope Check|Page 2516 > < Oscilloscope Check