Evaporator Temperature Sensor / Switch: Testing and Inspection

OUTSIDE THERMO SENSOR INTERNAL RESISTANCE CHECK

Check the internal resistance of the outside thermo sensor are at the standard values at temperatures of 20°C (68°F) and 40°C (104°F).

Standard value:

Approximately 1,200 Ohm [at 20°C (68°C)]
Approximately 500 Ohm [at 40°C (104°C)]