mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Ambient Temperature Sensor / Switch HVAC|Locations|Page 5658 > < Ambient Temperature Sensor / Switch HVAC|Locations|Page 5656
Page 1
background image

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

OUTSIDE THERMO SENSOR INTERNAL RESISTANCE CHECK

Check the internal resistance of the outside thermo sensor are at the standard values at temperatures of 20° C (68° F) and 40° C (104° F).

Standard value:
Approximately 1,200 Ohms [at 20° C (68° C)]
Approximately 500 Ohms [at 40° C (104° C)]

Ambient Temperature Sensor / Switch HVAC|Locations|Page 5658 > < Ambient Temperature Sensor / Switch HVAC|Locations|Page 5656