mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4182 > < Initial Inspection and Diagnostic Overview|Page 4180
Page 2
background image

2. Connect a pressure gauge and a pedal depression gauge as shown in the illustration and bleed air from the pressure gauge.
3. Perform the operation test without booster according to the following method.

1. Depress the pedal repeatedly more than 40 times with the ignition switch at "LOCK" (OFF) position to bleed pressure from the HBB power

supply system. Measure the relation between the depressing force and the hydraulic pressure.

Standard Value 

4. Perform the operation test with booster according to the following method.

1. Turn ON the ignition switch and measure the relation between the depressing force and the hydraulic pressure after pump motor was stopped.

Standard Value 

BRAKE WARNING LIGHT AND BUZZER OPERATION CHECK 

CAUTION:  Perform the test 120 seconds or more after turning the ignition switch ON.

1. Perform the test 120 seconds or more after turning the ignition switch ON.
2. Chock the wheel and start the engine.
3. Hold the engine at the idling condition for more than 120 seconds.

4. Release the parking brake and fully depress the brake pedal repeatedly 15 to 20 times in 10 seconds. Confirm that the warning light comes on and

Initial Inspection and Diagnostic Overview|Page 4182 > < Initial Inspection and Diagnostic Overview|Page 4180