mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 5006 > < Symptom Related Diagnostic Procedures|Page 5004
Page 3
background image

2. Measure the voltage between AC inverter connector D-128 (terminal No. 1) and the body ground.

-

The voltage should measure approximately 2 volts (battery positive voltage).

Q: Does the voltage measure battery voltage?

YES: Go to Step 5.

NO: Go to Step 3.

STEP 3. Check the wiring harness between AC inverter connector D-128 (terminal No. 1) and fusible link (34).

NOTE:  Before the wiring harness check, check intermediate connector C-32 and C-35, ETACS-ECU connector C-308,and then repair them if
necessary.

Q: Is the wiring harness between AC inverter connector D-128 (terminal No. 1) and fusible link (34) in good condition?

YES: Go to Step 4.

NO: Repair the wiring harness between AC inverter connector D-128 and fusible link (34).

STEP 4. Retest the system

Q: Is the check result normal?

YES: The trouble can be an intermittent malfunction (Refer to How to use Troubleshooting/inspection Service Points - How to Cope with
Intermittent Malfunction).

NO: Carry out the troubleshooting again.

STEP 5. Measure the voltage at AC inverter connector D-128.

1. Disconnect the connector, and measure at the wiring harness side.
2. Turn the ignition switch to the "ON" position.

3. Measure the voltage between AC inverter connector D-128 (terminal No. 3) and the body ground.

-

The voltage should measure approximately 2 volts (battery positive voltage).

Q: Does the voltage measure battery voltage?

YES: Go to Step 8.

Symptom Related Diagnostic Procedures|Page 5006 > < Symptom Related Diagnostic Procedures|Page 5004