Actuator: Service and Repair

ELECTRONIC CONTROL COUPLING

REMOVAL AND INSTALLATION

Removal Steps 1-5

INSTALLATION SERVICE POINTS

]]A[[ ELECTRONIC CONTROL COUPLING

INSTALLATION

1. Check that the length of the electronic control coupling stud bolt (A) is within the standard value range.

Standard value: 22.3 - 25.1 mm (0.88 - 0.99 inch)

2. If it exceeds either of the limits, clean the threads for the electronic control coupling and replace the stud bolt.

Tightening torque: 15 ± 3 Nm (11 ± 2 ft-lb)