Outlander AWD L4-2.4L SOHC (2003)
combination meter (LH) : Go to Step 45.
combination meter (RH): Go to Step 47.
combination meter (both right and left): Go to Step 49.
LH side only : Refer to Inspection Procedure K-1 "Turn-signal lights does not flash when the turn-signal light switch is turned on."
RH side only : Refer to Inspection Procedure K-1 "Turn-signal lights does not flash when the turn-signal light switch is turned on."
Both LH and RH sides : Refer to Inspection Procedure K-2 "Hazard warning light does not illuminate."
STEP 2. Check the ground circuit to the front combination light (LH). Test at front combination light (LH) connector A-16.
1. Disconnect front combination light (LH) connector A-16 and measure the resistance available at the wiring harness side of the connector.
2. Measure the resistance value between terminal 3 and ground.
-
The resistance should equal 2 ohms or less.
Q: Is the measured resistance 2 ohms or less?
YES: Go to Step 5.
NO: Go to Step 3.
STEP 3. Check front combination light (LH) connector A-16 for loose, corroded or damaged terminals, or terminals pushed back in the
connector.
Q: Is the front turn-signal (LH) connector A-16 in good condition?
YES: Go to Step 4.