Raider V6-3.7L SOHC (2006)
1. Carefully position the Occupant Restraint Controller (ORC) (1) onto the studs of the ORC mount (4) on the floor panel transmission tunnel.
When the ORC is correctly positioned, the arrow on the ORC label will be pointed forward in the vehicle and the ORC connector receptacles
will be facing the left side of the vehicle.
2. Install and tighten the three nuts (2) that secure the ORC to the studs of the ORC mount that is welded onto the floor panel transmission tunnel.
Tighten the nuts to 6 Nm (50 in. lbs.).
3. Reinstall the floor distribution duct onto the bottom of the heater.air conditioner housing.
5. Reconnect the instrument panel (1) and body (3) wire harness connectors to the ORC (2) connector receptacles located on the left facing side
of the module. Be certain that the latches and the red CPA locks on both connectors are each fully engaged.
6. Do not reconnect the battery negative cable at this time. The supplemental restraint system verification test procedure should be performed
following service of any supplemental restraint system component.