mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Refueling Vapor Recovery System > < Leak Detection Pump, Evaporative System|Description and Operation|Page 2328
Page 3
background image

2. Be sure O-ring (2) and EVAP canister opening are clean.

CAUTION:  The electrical connector (3) on the ESIM switch must be in 3 O'clock position after installation. This step must be done for
proper switch operation.

3. Position ESIM switch (2) into EVAP canister (1) and rotate until electrical connector is in 3 O'clock position (3).
4. Connect electrical connector.
5. Connect plastic lines to ESIM switch.