Starion L4-2555cc 2.6L SOHC Turbo (1988)
Fig. 39 Testing control relay coils L1 & L2.
Fig. 40 Testing control relay coils L3.
1987 - 88 Models
1.
Check continuity between control relay terminals, Fig. 38, with relay coil energized and not energized as shown, Fig. 39. To energize coils, L1
and L2, apply battery voltage across terminals 6 and 4.
2.
Check continuity between control relay terminals, Fig. 38, with relay coil energized and not energized as shown, Fig. 40. To energize coil, L3,
apply battery voltage across terminals 8 and 4.
3.
If test results are not satisfactory, replace control relay.