Workshop Manuals Factory service & repair Nissan and Datsun
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Nissan and Datsun Altima V6-3.5L (VQ35) (2003)03 · Maintenance
03 · Maintenance

Refrigerant: Specifications (page 4 of 4)

Make
Nissan and Datsun
Model
Altima
Engine
V6-3.5L (VQ35)
Year
2003
Section
Fluids › Refrigerant
MaintenanceSpecifications · page 4 of 4
background image

Check all around the service valves. Ensure service valve caps are secured on the service valves (to prevent leaks).

NOTE:  After removing A/C manifold gauge set from service valves, wipe any residue from valves to prevent any false readings by leak detector.

Cooling unit (Evaporator)
With engine OFF, turn blower fan on "High" for at least 15 seconds to dissipate any refrigerant trace in the cooling unit. Wait a minimum of 10
minutes
 accumulation time (refer to the manufacturer's recommended procedure for actual wait time) before inserting the leak detector probe into
the drain hose.

Keep the probe inserted for at least 10 seconds. Use caution not to contaminate the probe tip with water or dirt that may be in the drain hose.

5. If a leak detector detects a leak, verify at least once by blowing compressed air into area of suspected leak, then repeat check as outlined above.
6. Do not stop when one leak is found. Continue to check for additional leaks at all system components. If no leaks are found, perform steps 7 - 10.
7. Start engine.
8. Set the heater A/C control as follows;

a. A/C switch: ON
b. Face mode
c. Intake position: Recirculation
d. Max cold temperature
e. Fan speed: High

9. Run engine at 1,500 rpm for at least 2 minutes.

10. Turn engine off and perform leak check again following steps 4 through 6 above.

Refrigerant leaks should be checked immediately after stopping the engine. Begin with the leak detector at the compressor. The pressure on the
high pressure side will gradually drop after refrigerant circulation stops and pressure on the low pressure side will gradually rise, as shown in the
graph. Some leaks are more easily detected when pressure is high.

11. Before connecting ACR4 to vehicle, check ACR4 gauges. No refrigerant pressure should be displayed. If pressure is displayed, recover refrigerant

from equipment lines and then check refrigerant purity.

12. Confirm refrigerant purity in supply tank using ACR4 and refrigerant identifier.
13. Confirm refrigerant purity in vehicle A/C system using ACR4 and refrigerant identifier.
14. Discharge A/C system using approved refrigerant recovery equipment. Repair the leaking fitting or component as necessary.
15. Evacuate and recharge A/C system and perform the leak test to confirm no refrigerant leaks.
16. Conduct A/C performance test to ensure system works properly.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 2003 Nissan Altima 3.5L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.