Catalytic Converter: Technical Service Bulletins
Oxygen Sensor - Thread Cleaning and Other Precautions

Classification:
TE98-005

Reference:
NTB98-089

Date:
November 15, 1998

02 SENSOR THREAD REPAIR FOR EXHAUST TUBE, 
EXHAUST MANIFOLD AND CATALYTIC CONVERTER

APPLIED VEHICLE:
All models with 02 sensors

SERVICE INFORMATION

When removing a front or rear 02 sensor, material may remain on the internal threads of the exhaust tube, catalytic converter, or exhaust manifold.
Special service tools (see Figure 1) are available to clean the internal threads in such cases. This will minimize the need to replace these components.
These required special tools will be mailed separately.

Use this bulletin when replacing 02 sensors as part of the 1996 Maxima OBDII Campaign (NTB98-073) or whenever there is a need to clean 02 sensor
threads.

NOTE:

This tool is not to be used for tapping threads.

SERVICE PROCEDURE

CAUTION:

Always follow these general guidelines when servicing 02 sensors.

Do not apply severe shock to the sensor when installing it. Do not use an impact wrench for installing it.

Discard any sensor that has been dropped.

Never attempt to clean an 02 sensor by applying solvent to it.

Anti-seize must only be applied to the threads, not the sensing element.

1.

Remove the 02 sensor from the exhaust tube, exhaust manifold, or catalytic converter.

2.

Select the correct thread repair tool based on the thread diameter of the removed 02 sensor (see Figure 1).

^

Zirconia 02 sensors use the 18 mm diameter tool: J-43897-18.