nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Testing and Inspection
Page 1
background image

Condenser HVAC: Service and Repair

    When installing new condenser, it is not necessary to add refrigerant oil when there are no signs of a major oil leak, except on the Sentra.
When installing new condenser on Sentra that shows no sign of oil leak, add .3 oz. of new refrigerant oil. On all models that show signs of major
oil leak, except 200SX, 300ZX or Sentra, add 1.7 oz. of new refrigerant oil. On Sentra and 300ZX that show signs of major oil leak, add 2 oz. of
new refrigerant oil.
 

1.

Disconnect battery ground cable and discharge system refrigerant.

2.

Remove radiator grille.

3.

Disconnect refrigerant lines at condenser, plugging all openings.

4.

Remove condenser cooling fan.

5.

Remove radiator attaching bolts and nuts.

6.

Remove condenser attaching bolts, then the condenser while pushing radiator toward engine.

7.

Reverse procedure to install, evacuate and recharge system, then check for leaks. 

Condenser Fan > < Condenser HVAC|Testing and Inspection